Mobile Battery-Buffered
EV Charging System
e-Pump M260
e-Pump M520
Application Scenario
CONSTRUCTION SITE MINING EV FLEET MOBILITY
System Layout
System Demonstration
Grid
Load
EV CarePump M SystemATS
AC Combiner Liquid-Cooling
Module
PCS Module
Master Control
ModulePCS Module
Battery Module
*Vehicle Not Included
- Support Center
- Electric Vehicle Infrastructure
- Specification Sheet
e-Pump S240/e-Pump S480 Stationary Battery-Buffered Ev Charging Systems
Technical Specifications
-25°C-50°C(over 45°C derating)
≤95%, No condensation
–20°C to 30°C,
Up to 95% RH, non-condensing,
State of Energy (SoE): 50% initial
2000m / 6561ft
<80 dB(A)
Type A
Non explosive hazardous, No toxic & harmful gases
Without strong vibration and shock,
no strong electromagnetic interference
IP54
General Parameters
Ambient Temperature
Humidity
Storage Conditions
Altitude
Noise Level @1m
EMC Emission
Medium
Interference
System IP Rating
DC fast charging
240
200~1000*
250
TN-S.TN-C, TN-C-S, TT (required external RCD)
3P +N + PE
Overcurrent, overvoltage, undervoltage,
integrated surge protection,ground fault
including DC leakage protection, door
opening protection
≥0.99
<5%
≥ 94% (peak)
750*640*1750mm / 29.5*25*68.9in
380kg / 837.7lb
Charging System
Charging Type
DC Output Power(kW)
DC Output Voltage(Vdc)
Maximum Current(A)
Distribution Systems
Connector Type
Protection
Power Factor (Full Load)
THDi
Efficiency
Dimensions (W*D*H)
Weight
261
≤0.5C
≤0.8C
≥97%
IP65
Liquid-cooling
Aerosol Extinguishing
1800*1500*1750mm / 70.8*59*68.9in
2850kg / 6283lb
Energy Storage System
Battery Capacity(kWh)
Battery Charging Rate
Battery Discharge Rate
Battery Efficiency
Battery Module IP Rating
Battery Cooling System
Thermal Control Management
Dimensions (W*D*H)
Weight
250
266
480
-15%~+10%(settable)
60Hz(settable)
330.8
1 (leading)~1(lagging)
>0.99
<3%
110%
AC Input
Rated AC Output Power(kW)
Max. AC Output Power(kVA)
Rated Output Voltage(Vac)
Output Voltage Range
Grid Frequency Range(Hz)
Max. Output Current(A)
Power Factor
Adjustable Power Factor
THDi
Overloading Capability
UL9540A
UL2202, FCC, EN 61851-1,
EN 61851-23, EN 61000-2/-4
UL 1973, UL9540A, UL9540
FCC, IEC 62619, EN62109-1/2
EN61000-6-2/4, UN38.3
Standard
Battery
EV Charger
System Level
Packaging & Shipping Details
1 Unit
2000*1600*2000mm
78x62x78
3050kg/6725lbs
260kWh
1 System
3480kg/7675lbs
520kWh
1 System
6930kg/15,278lbs
Battery Cabinet
1800*1500*1750mm
70x60x68in
2850kg/6285lbs
OTR Trucking
4 Systems
13,920kg/30,688lbs
1 Unit
900*800*2000mm
35x31.5x78in
430kg/950lbs
Charging Module
750*640*1750mm
30x25x69in
380kg/840lbs
OTR Trucking
2 Systems
13,860kg/30,556lbs
*Constant power from 300~1000
≤95%, No condensation
–20°C to 30°C,
Up to 95% RH, non-condensing,
State of Energy (SoE): 50% initial
2000m / 6561ft
<80 dB(A)
Type A
Non explosive hazardous, No toxic & harmful gases
Without strong vibration and shock,
no strong electromagnetic interference
IP54
General Parameters
Ambient Temperature
Humidity
Storage Conditions
Altitude
Noise Level @1m
EMC Emission
Medium
Interference
System IP Rating
DC fast charging
240
200~1000*
250
TN-S.TN-C, TN-C-S, TT (required external RCD)
3P +N + PE
Overcurrent, overvoltage, undervoltage,
integrated surge protection,ground fault
including DC leakage protection, door
opening protection
≥0.99
<5%
≥ 94% (peak)
750*640*1750mm / 29.5*25*68.9in
380kg / 837.7lb
Charging System
Charging Type
DC Output Power(kW)
DC Output Voltage(Vdc)
Maximum Current(A)
Distribution Systems
Connector Type
Protection
Power Factor (Full Load)
THDi
Efficiency
Dimensions (W*D*H)
Weight
261
≤0.5C
≤0.8C
≥97%
IP65
Liquid-cooling
Aerosol Extinguishing
1800*1500*1750mm / 70.8*59*68.9in
2850kg / 6283lb
Energy Storage System
Battery Capacity(kWh)
Battery Charging Rate
Battery Discharge Rate
Battery Efficiency
Battery Module IP Rating
Battery Cooling System
Thermal Control Management
Dimensions (W*D*H)
Weight
250
266
480
-15%~+10%(settable)
60Hz(settable)
330.8
1 (leading)~1(lagging)
>0.99
<3%
110%
AC Input
Rated AC Output Power(kW)
Max. AC Output Power(kVA)
Rated Output Voltage(Vac)
Output Voltage Range
Grid Frequency Range(Hz)
Max. Output Current(A)
Power Factor
Adjustable Power Factor
THDi
Overloading Capability
UL9540A
UL2202, FCC, EN 61851-1,
EN 61851-23, EN 61000-2/-4
UL 1973, UL9540A, UL9540
FCC, IEC 62619, EN62109-1/2
EN61000-6-2/4, UN38.3
Standard
Battery
EV Charger
System Level
Packaging & Shipping Details
1 Unit
2000*1600*2000mm
78x62x78
3050kg/6725lbs
260kWh
1 System
3480kg/7675lbs
520kWh
1 System
6930kg/15,278lbs
Battery Cabinet
1800*1500*1750mm
70x60x68in
2850kg/6285lbs
OTR Trucking
4 Systems
13,920kg/30,688lbs
1 Unit
900*800*2000mm
35x31.5x78in
430kg/950lbs
Charging Module
750*640*1750mm
30x25x69in
380kg/840lbs
OTR Trucking
2 Systems
13,860kg/30,556lbs
*Constant power from 300~1000